Skip to main content
ASTM F136 Ti-6Al-4V ELI & ISO 5832-1 316LVM • AO/ASIF TRAUMA HARDWARE
Locking Compression Plates (LCP), Ti-6Al-4V Implants & Trauma Fixation Brief

Implant-Grade Ti-6Al-4V ELI (ISO 5832-3 / ASTM F136) vs 316LVM Stainless Steel (ISO 5832-1) in Trauma Fixation

Metallurgical comparison of vacuum-melted 316LVM austenitic steel and Extra-Low Interstitial Titanium (Ti-6Al-4V ELI) across Young's modulus, MRI artifact reduction, and fatigue strength.

Implant-Grade Ti-6Al-4V ELI (ISO 5832-3 / ASTM F136) vs 316LVM Stainless Steel (ISO 5832-1) in Trauma Fixation
Technical Specialist
Dr. Tariq Mahmood Implant Grade Titanium & ISO 5832-3 Metallurgy Advisor
Quality & Technical Standard

Reviewed against ASTM F136 / ISO 5832-3 Ti-6Al-4V ELI titanium and ISO 5832-1 316LVM implant metallurgy, locking thread geometry, and AO trauma standards.

Monograph Telemetry
1 min read
On this page (2)
  1. 1. Mechanical & Physical Properties Comparison
  2. 2. Color-Coded Type II Anodization & Oxide Layer Biocompatibility

Implant metallurgy governs long-term biocompatibility, stress-shielding remodeling, and post-operative CT/MRI diagnostic clarity. OrthoValley manufactures complete trauma fixation lines in both vacuum-arc remelted 316LVM stainless steel (ISO 5832-1 / ASTM F138) and Extra-Low Interstitial Titanium alloy Ti-6Al-4V ELI (ISO 5832-3 / ASTM F136).

1. Mechanical & Physical Properties Comparison

Metallurgical Property316LVM Stainless Steel (ISO 5832-1)Ti-6Al-4V ELI Titanium (ISO 5832-3)Cortical Human Bone
Young's Modulus (Elasticity)~193 GPa (High stiffness)~110 GPa (Closer to cortical bone)15 – 30 GPa
Ultimate Tensile Strength860 – 1,000 MPa (Cold-worked)860 – 965 MPa (Annealed ELI)130 – 150 MPa
MRI / CT Scatter ArtifactModerate ferromagnetic distortionMinimal artifact; MRI conditional safeN/A
Nickel HypersensitivityContains 13–15% Ni100% Nickel-Free (TiO2 passive layer)N/A

2. Color-Coded Type II Anodization & Oxide Layer Biocompatibility

Electrochemical Type II and Type III anodization not only color-codes fragment diameters (Blue for 2.0 mm, Gold for 2.4/2.7 mm, Magenta/Green for 3.5 mm, Grey/Gold for 4.5 mm) for instant scrub-nurse identification, but also thickens the inert TiO₂ barrier layer to inhibit metallic ion release.

Technical Author & Specialist Review

Dr. Tariq Mahmood

Implant Grade Titanium & ISO 5832-3 Metallurgy Advisor

Reviewed against ASTM F136 / ISO 5832-3 Ti-6Al-4V ELI titanium and ISO 5832-1 316LVM implant metallurgy, locking thread geometry, and AO trauma standards.